{"id":6153,"date":"2021-09-20T14:19:54","date_gmt":"2021-09-20T12:19:54","guid":{"rendered":"https:\/\/thenex-test.de\/?page_id=6153"},"modified":"2021-09-29T09:59:17","modified_gmt":"2021-09-29T07:59:17","slug":"industrial-burners","status":"publish","type":"page","link":"https:\/\/thenex.com\/de\/industrial-burners\/","title":{"rendered":"Industrial Burners"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-padding-top:60px;--awb-padding-right:60px;--awb-padding-bottom:60px;--awb-padding-left:60px;--awb-bg-color:#ffffff;--awb-bg-color-hover:#ffffff;--awb-bg-size:cover;--awb-border-color:#e2e2e2;--awb-border-top:1px;--awb-border-right:1px;--awb-border-bottom:1px;--awb-border-left:1px;--awb-border-style:solid;--awb-margin-top:0px;--awb-margin-bottom:0px;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-title title fusion-title-1 fusion-title-center fusion-title-text fusion-title-size-one\"><div class=\"title-sep-container title-sep-container-left\"><div class=\"title-sep sep-single sep-solid\" style=\"border-color:#e0dede;\"><\/div><\/div><span class=\"awb-title-spacer\"><\/span><h1 class=\"fusion-title-heading title-heading-center\" style=\"margin:0;\">Industrial Burners<\/h1><span class=\"awb-title-spacer\"><\/span><div class=\"title-sep-container title-sep-container-right\"><div class=\"title-sep sep-single sep-solid\" style=\"border-color:#e0dede;\"><\/div><\/div><\/div><div class=\"fusion-text fusion-text-1\"><p>Industrial Burners are the flagship products of BCE and are generally supplied to industrial boiler manufacturers for steam and power generation or directly to clients within combustion system revamping. We could adapt such products for a large number of operating conditions, as they are designed and manufactured on job-by-job basis. Industrial Burners can reach high firing rate and, at the same time, satisfy the most stringent restrictions on pollutant emissions.<\/p>\n<h2><strong><em>1. Low NOx Burners DMPJE<\/em><\/strong><\/h2>\n<p>Low NOx burners DMPJE are equipped with two air registers suitable for any kind of liquid and\/or gaseous fuel with the possibility to fire one or more fuels at the same time. Combustion air is divided into \u201cprimary\u201d and \u201csecondary\u201d flows resulting in stratified combustion.<\/p>\n<p><img decoding=\"async\" class=\"lazyload wp-image-4743 alignnone\" src=\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/14-768x384-12.jpg\" data-orig-src=\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/14-768x384-12.jpg\" alt=\"\" width=\"770\" height=\"385\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27770%27%20height%3D%27385%27%20viewBox%3D%270%200%20770%20385%27%3E%3Crect%20width%3D%27770%27%20height%3D%27385%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/14-768x384-12-200x100.jpg 200w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/14-768x384-12-300x150.jpg 300w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/14-768x384-12-400x200.jpg 400w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/14-768x384-12-600x300.jpg 600w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/14-768x384-12.jpg 768w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 770px) 100vw, 770px\" \/><\/p>\n<p><strong>Technical data<\/strong><\/p>\n<table style=\"height: 230px;\" width=\"306\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">Firing rate<\/td>\n<td valign=\"top\">up to 60 MW<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Flame dimensions(*)<\/td>\n<td valign=\"top\">adjustable<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Materials<\/td>\n<td valign=\"top\">carbon steel<\/p>\n<p>stainless steel<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Combustion air<\/td>\n<td valign=\"top\">up to 550 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Turndown<\/td>\n<td valign=\"top\">6:1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Pressure drop<\/td>\n<td valign=\"top\">150 \u2013 200 mm wg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Natural gas firing<\/p>\n<table style=\"height: 48px;\" width=\"306\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">NOx<\/td>\n<td valign=\"top\">140 \u2013 150 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CO<\/td>\n<td valign=\"top\">30 mg\/Nm3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Heavy fuel oil firing (N content 0,2 % by weight)<\/p>\n<table style=\"height: 75px;\" width=\"306\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">NOx<\/td>\n<td valign=\"top\">400 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CO<\/td>\n<td valign=\"top\">100 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Particulate<\/td>\n<td valign=\"top\">50 mg\/Nm3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><\/h2>\n<h2><strong><em>2.<span class=\"Apple-converted-space\">\u00a0 <\/span>Ultra Low NOx Burners DTPJE<\/em><\/strong><\/h2>\n<p>Ultra Low NOx burners DTPJE are designed to satisfy the most stringent restrictions on pollutant emissions on fuel gas firing, with or without Flue Gas Recirculation (FGR), while providing high combustion efficiency and reliability with all kinds of gaseous fuels.<\/p>\n<p><img decoding=\"async\" class=\"lazyload alignnone wp-image-4749\" src=\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/16-768x384-14.jpg\" data-orig-src=\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/16-768x384-14.jpg\" alt=\"\" width=\"770\" height=\"385\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27770%27%20height%3D%27385%27%20viewBox%3D%270%200%20770%20385%27%3E%3Crect%20width%3D%27770%27%20height%3D%27385%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/16-768x384-14-200x100.jpg 200w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/16-768x384-14-300x150.jpg 300w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/16-768x384-14-400x200.jpg 400w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/16-768x384-14-600x300.jpg 600w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/16-768x384-14.jpg 768w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 770px) 100vw, 770px\" \/><\/p>\n<p><strong>Technical data<\/strong><\/p>\n<table style=\"height: 390px;\" width=\"300\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">Firing rate<\/td>\n<td valign=\"top\">up to 60 MW<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Flame dimensions(*)<\/td>\n<td valign=\"top\">adjustable<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Materials<\/td>\n<td valign=\"top\">carbon steel<\/p>\n<p>stainless steel<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Combustion air<\/td>\n<td valign=\"top\">up to 550 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Turndown<\/td>\n<td valign=\"top\">7:1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Pressure drop<\/td>\n<td valign=\"top\">200 \u2013 250 mm wg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Natural gas firing w\/o flue gas recirculation<\/p>\n<table style=\"height: 108px;\" width=\"300\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">NOx<\/td>\n<td valign=\"top\">75 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CO<\/td>\n<td valign=\"top\">30 mg\/Nm3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Natural gas firing with flue gas recirculation<\/p>\n<table style=\"height: 116px;\" width=\"300\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">NOx<\/td>\n<td valign=\"top\">55 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CO<\/td>\n<td valign=\"top\">30 mg\/Nm3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><\/h2>\n<h2><strong><em>3. Low NOx Burners MPJE <\/em><\/strong><\/h2>\n<p>Low NOx Burners MPJE\u00a0are equipped with one air register suitable for any kind of liquid and\/or gaseous fuel with the possibility to fire one or more fuels at the same time. These are our classic burners and we have a large number of references around the world.<\/p>\n<p><strong>Technical Data<\/strong><\/p>\n<table style=\"height: 390px;\" width=\"300\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">Firing rate<\/td>\n<td valign=\"top\">up to 60 MW<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Flame dimensions(*)<\/td>\n<td valign=\"top\">adjustable<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Materials<\/td>\n<td valign=\"top\">carbon steel<\/p>\n<p>stainless steel<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Combustion air<\/td>\n<td valign=\"top\">up to 550 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Turndown<\/td>\n<td valign=\"top\">6:1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Pressure drop<\/td>\n<td valign=\"top\">150 \u2013 200 mm wg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Natural gas firing<\/p>\n<table style=\"height: 118px;\" width=\"300\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">NOx<\/td>\n<td valign=\"top\">200 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CO<\/td>\n<td valign=\"top\">30 mg\/Nm3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Heavy fuel oil firing (N content 0,2 % by weight)<\/p>\n<table style=\"height: 174px;\" width=\"300\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">NOx<\/td>\n<td valign=\"top\">450 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CO<\/td>\n<td valign=\"top\">100 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Particulate<\/td>\n<td valign=\"top\">50 mg\/Nm3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><\/h2>\n<h2><strong><em>4. Duct burners<\/em><\/strong><\/h2>\n<p>Duct Burners are usually used in combined cycle and they can work either with fresh air (when gas turbine is turned off) or exhaust gas. For this reason they are made from stainless steel in order to resist to the high temperature inside the duct (up to 500 \u00b0C).<\/p>\n<p><a href=\"https:\/\/thenex-test.de\/es\/burners-by-bce\/13-1170x240-16\/\" rel=\"attachment wp-att-4740\"><img decoding=\"async\" class=\"lazyload alignnone size-full wp-image-4740\" src=\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/13-1170x240-16.jpg\" data-orig-src=\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/13-1170x240-16.jpg\" alt=\"\" width=\"1170\" height=\"240\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%271170%27%20height%3D%27240%27%20viewBox%3D%270%200%201170%20240%27%3E%3Crect%20width%3D%271170%27%20height%3D%27240%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/13-1170x240-16-200x41.jpg 200w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/13-1170x240-16-300x62.jpg 300w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/13-1170x240-16-400x82.jpg 400w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/13-1170x240-16-600x123.jpg 600w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/13-1170x240-16-768x158.jpg 768w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/13-1170x240-16-800x164.jpg 800w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/13-1170x240-16-1024x210.jpg 1024w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/13-1170x240-16.jpg 1170w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1170px) 100vw, 1170px\" \/><\/a><\/p>\n<p><strong>Technical Data<\/strong><\/p>\n<table style=\"height: 389px;\" width=\"320\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">Firing rate<\/td>\n<td valign=\"top\">up to 15 MW per row<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Flame dimensions(*)<\/td>\n<td valign=\"top\">1.500 mm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Materials<\/td>\n<td valign=\"top\">carbon steel<\/p>\n<p>stainless steel<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Combustion air<\/td>\n<td valign=\"top\">up to 550 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Turndown<\/td>\n<td valign=\"top\">10:1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Pressure drop<\/td>\n<td valign=\"top\">10 \u2013 20 mm wg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Natural gas firing with fresh air<\/p>\n<table style=\"height: 108px;\" width=\"320\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">NOx<\/td>\n<td valign=\"top\">30 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CO<\/td>\n<td valign=\"top\">30 mg\/Nm3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Natural gas firing with gas turbine exhaust<\/p>\n<table style=\"height: 106px;\" width=\"320\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">NOx<\/td>\n<td valign=\"top\">&#8211; mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CO<\/td>\n<td valign=\"top\">&#8211; mg\/Nm3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><\/h2>\n<h2><strong><em>5. VRGO burners<\/em><\/strong><\/h2>\n<p>BCE burners type \u201cVRGO\u201d are typically equipped with a series of gas lance and one central gas lance. If designed to burn heavy fuel oil or diesel oil, the central gas lance is replaced with fuel oil\/diesel atomizer.<\/p>\n<p>The \u201cVRGO\u201d burners are designed to reach high efficiency combustion level and can be supplied as part of new combustion systems as well as revamping of existing plants.<\/p>\n<p><a href=\"https:\/\/thenex-test.de\/es\/burners-by-bce\/18-1170x240-18\/\" rel=\"attachment wp-att-4752\"><img decoding=\"async\" class=\"lazyload alignnone size-full wp-image-4752\" src=\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/18-1170x240-18.jpg\" data-orig-src=\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/18-1170x240-18.jpg\" alt=\"\" width=\"1170\" height=\"240\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%271170%27%20height%3D%27240%27%20viewBox%3D%270%200%201170%20240%27%3E%3Crect%20width%3D%271170%27%20height%3D%27240%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/18-1170x240-18-200x41.jpg 200w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/18-1170x240-18-300x62.jpg 300w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/18-1170x240-18-400x82.jpg 400w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/18-1170x240-18-600x123.jpg 600w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/18-1170x240-18-768x158.jpg 768w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/18-1170x240-18-800x164.jpg 800w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/18-1170x240-18-1024x210.jpg 1024w, https:\/\/thenex.com\/wp-content\/uploads\/2019\/11\/18-1170x240-18.jpg 1170w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 1170px) 100vw, 1170px\" \/><\/a><\/p>\n<p><strong>Technical Data<\/strong><\/p>\n<table style=\"height: 390px;\" width=\"300\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">Firing rate<\/td>\n<td valign=\"top\">up to 25 MW<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Flame dimensions(*)<\/td>\n<td valign=\"top\">adjustable<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Materials<\/td>\n<td valign=\"top\">carbon steel<\/p>\n<p>stainless steel<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Combustion air<\/td>\n<td valign=\"top\">up to 400 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Turndown<\/td>\n<td valign=\"top\">5:1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Pressure drop<\/td>\n<td valign=\"top\">50 \u2013 100 mm H2O<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Natural gas firing<\/p>\n<table style=\"height: 122px;\" width=\"300\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">NOx<\/td>\n<td valign=\"top\">200 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CO<\/td>\n<td valign=\"top\">50 mg\/Nm3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Heavy fuel oil firing (N content 0,2 % by weight)<\/p>\n<table style=\"height: 176px;\" width=\"300\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">NOx<\/td>\n<td valign=\"top\">450 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CO<\/td>\n<td valign=\"top\">100 mg\/Nm3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Particulate<\/td>\n<td valign=\"top\">50 mg\/Nm3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><\/h2>\n<h2><strong><em>6. Off Gas and Low LHV Burners<\/em><\/strong><\/h2>\n<p>These burners are supplied with external gas scroll through which the gaseous stream is injected into the combustion chamber. Each burner is also supplied with gas lances and a central gas gun which are necessary to heat up the system before syngas injection.<\/p>\n<p>Sometimes,s when the calorific value is very low, the central gas gun or a continuous pilot is kept operational.<\/p>\n<p>If there is the presence of two syngas streams which have very different characteristics in terms of volume and operating conditions, we could provide burners with double external gas scroll.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-padding-top:60px;--awb-padding-right:60px;--awb-padding-bottom:60px;--awb-padding-left:60px;--awb-bg-color:#ffffff;--awb-bg-color-hover:#ffffff;--awb-bg-size:cover;--awb-border-color:#e2e2e2;--awb-border-top:1px;--awb-border-right:1px;--awb-border-bottom:1px;--awb-border-left:1px;--awb-border-style:solid;--awb-margin-top:20px;--awb-margin-bottom:20px;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-column-wrapper-legacy\"><div class=\"fusion-aligncenter\"><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-1 fusion-button-default-span fusion-button-default-type\" target=\"_self\" href=\"mailto:request@thenex.com\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">For inquiries or further requests, please feel free to contact our Sales Team.<\/span><\/a><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":5,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-6153","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Industrial Burners - thenex GmbH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/thenex.com\/de\/industrial-burners\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Industrial Burners - thenex GmbH\" \/>\n<meta property=\"og:url\" content=\"https:\/\/thenex.com\/de\/industrial-burners\/\" \/>\n<meta property=\"og:site_name\" content=\"thenex GmbH\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/thenexgmbh\" \/>\n<meta property=\"article:modified_time\" content=\"2021-09-29T07:59:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/14-768x384-12.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"7\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/thenex.com\/de\/industrial-burners\/\",\"url\":\"https:\/\/thenex.com\/de\/industrial-burners\/\",\"name\":\"Industrial Burners - thenex GmbH\",\"isPartOf\":{\"@id\":\"https:\/\/thenex.com\/de\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/thenex.com\/de\/industrial-burners\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/thenex.com\/de\/industrial-burners\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/14-768x384-12.jpg\",\"datePublished\":\"2021-09-20T12:19:54+00:00\",\"dateModified\":\"2021-09-29T07:59:17+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/thenex.com\/de\/industrial-burners\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/thenex.com\/de\/industrial-burners\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/thenex.com\/de\/industrial-burners\/#primaryimage\",\"url\":\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/14-768x384-12.jpg\",\"contentUrl\":\"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/14-768x384-12.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/thenex.com\/de\/industrial-burners\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/thenex.com\/de\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Industrial Burners\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/thenex.com\/de\/#website\",\"url\":\"https:\/\/thenex.com\/de\/\",\"name\":\"thenex GmbH\",\"description\":\"WORLDWIDE INDUSTRIAL SERVICES SINCE 1900\",\"publisher\":{\"@id\":\"https:\/\/thenex.com\/de\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/thenex.com\/de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/thenex.com\/de\/#organization\",\"name\":\"thenex\",\"url\":\"https:\/\/thenex.com\/de\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/thenex.com\/de\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/thenex-test.de\/wp-content\/uploads\/2015\/09\/Thenex_Logo_2015_AVADA_350_Transparent.png\",\"contentUrl\":\"https:\/\/thenex-test.de\/wp-content\/uploads\/2015\/09\/Thenex_Logo_2015_AVADA_350_Transparent.png\",\"width\":350,\"height\":160,\"caption\":\"thenex\"},\"image\":{\"@id\":\"https:\/\/thenex.com\/de\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"http:\/\/www.facebook.com\/thenexgmbh\",\"https:\/\/www.instagram.com\/thenexgmbh\/\",\"https:\/\/www.linkedin.com\/company\/thenex-gmbh\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Industrial Burners - thenex GmbH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/thenex.com\/de\/industrial-burners\/","og_locale":"de_DE","og_type":"article","og_title":"Industrial Burners - thenex GmbH","og_url":"https:\/\/thenex.com\/de\/industrial-burners\/","og_site_name":"thenex GmbH","article_publisher":"http:\/\/www.facebook.com\/thenexgmbh","article_modified_time":"2021-09-29T07:59:17+00:00","og_image":[{"url":"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/14-768x384-12.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"7\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/thenex.com\/de\/industrial-burners\/","url":"https:\/\/thenex.com\/de\/industrial-burners\/","name":"Industrial Burners - thenex GmbH","isPartOf":{"@id":"https:\/\/thenex.com\/de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/thenex.com\/de\/industrial-burners\/#primaryimage"},"image":{"@id":"https:\/\/thenex.com\/de\/industrial-burners\/#primaryimage"},"thumbnailUrl":"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/14-768x384-12.jpg","datePublished":"2021-09-20T12:19:54+00:00","dateModified":"2021-09-29T07:59:17+00:00","breadcrumb":{"@id":"https:\/\/thenex.com\/de\/industrial-burners\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/thenex.com\/de\/industrial-burners\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/thenex.com\/de\/industrial-burners\/#primaryimage","url":"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/14-768x384-12.jpg","contentUrl":"https:\/\/thenex-test.de\/wp-content\/uploads\/2019\/11\/14-768x384-12.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/thenex.com\/de\/industrial-burners\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/thenex.com\/de\/"},{"@type":"ListItem","position":2,"name":"Industrial Burners"}]},{"@type":"WebSite","@id":"https:\/\/thenex.com\/de\/#website","url":"https:\/\/thenex.com\/de\/","name":"thenex GmbH","description":"WORLDWIDE INDUSTRIAL SERVICES SINCE 1900","publisher":{"@id":"https:\/\/thenex.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/thenex.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/thenex.com\/de\/#organization","name":"thenex","url":"https:\/\/thenex.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/thenex.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/thenex-test.de\/wp-content\/uploads\/2015\/09\/Thenex_Logo_2015_AVADA_350_Transparent.png","contentUrl":"https:\/\/thenex-test.de\/wp-content\/uploads\/2015\/09\/Thenex_Logo_2015_AVADA_350_Transparent.png","width":350,"height":160,"caption":"thenex"},"image":{"@id":"https:\/\/thenex.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/thenexgmbh","https:\/\/www.instagram.com\/thenexgmbh\/","https:\/\/www.linkedin.com\/company\/thenex-gmbh"]}]}},"_links":{"self":[{"href":"https:\/\/thenex.com\/de\/wp-json\/wp\/v2\/pages\/6153","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/thenex.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/thenex.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/thenex.com\/de\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/thenex.com\/de\/wp-json\/wp\/v2\/comments?post=6153"}],"version-history":[{"count":16,"href":"https:\/\/thenex.com\/de\/wp-json\/wp\/v2\/pages\/6153\/revisions"}],"predecessor-version":[{"id":8171,"href":"https:\/\/thenex.com\/de\/wp-json\/wp\/v2\/pages\/6153\/revisions\/8171"}],"wp:attachment":[{"href":"https:\/\/thenex.com\/de\/wp-json\/wp\/v2\/media?parent=6153"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}